İÇ ÇAP ÖLÇÜMLERİ G270
Additional information
Type | G270 |
---|---|
Display mm / inch | mm + inch |
Application | Internal measurement |
Measuring span Mes | 20 mm |
Measuring range Meb | 70 – 90 mm |
Range of indication Azb | 69,5 – 90,5 mm |
Numerical interval Zw | 0,01 / 0,02 mm |
Max. permissible errors G | 0,03 mm |
Repeatability limit r | 0,1 mm |
Messkraft F min. | 1,1 N |
Messkraft F max. | 6 N |
Type of measuring contact movable | HM-Ball Ø 1,0 mm |
Measuring contact movable Hb | 8,5 mm |
Type of measuring contact fixed | HM-Ball Ø 1,0 mm |
Measuring contact fixed Hf | 8,5 mm |
Measuring contact thickness max. | Ø 2,6 mm |
Measuring depth max. L | 85 mm |
Weight | 270 g |
Reference temperature | 20 °C |
Reference temperature | 10 – 30 °C |
Storage temperature | -10 – 50 °C |
Protection class | IP67 |
Interface Digimatic | order no. 1961-09 + 2482-07 |
Interface USB | order no. 1961-09 + 2482-05 |
Interface U-Wave® | order no. 1961-09 + 2482-04 + 2482-01 + 2482-02 |
Wooden box | 1732-45 |
Holding unit | 8004-50 |